Spray foam is the right call for rim joists, crawl space walls, sealed rooflines and odd framing. It's the wrong call when a cheaper blown-in top-up does the job. We spray open-cell and closed-cell foam in Dayton, Ohio, and we'll tell you which one your house needs, or whether it needs foam at all. Ask for a free estimate and we'll write it down.
Use closed-cell foam on rim joists, crawl space and basement walls, and anywhere moisture is a worry. Use open-cell foam on attic rooflines and interior walls when you want to spend less or quiet a room. Some houses need both.
Johns Manville rates its JM Corbond closed-cell foam at R-7.0 per inch, and says one inch is an air barrier and 1.5 inches a vapor barrier. Each product has its own data sheet, so we write the exact product and its figures into your scope.
Neither wins everywhere. We choose by the spot, not by what we'd rather sell. For what drives the price of each, see spray foam cost.

Foam earns its place where batts and loose-fill can't seal the gaps. These are the spots we spray most:
Walls that are already closed up can get injection foam. We drill small holes, fill the cavity and patch the holes. See wall insulation for existing homes.
Skip foam when something else fits the job better, or when the house isn't ready. We'll say so at the estimate. Here's when:
The worry is real, and it comes down to three things: a bad mix, hidden roof wood, and hard removal. All three can be avoided.
A bad mix. Foam sprayed off-ratio or onto cold surfaces can smell for weeks and cure wrong. The fix is a trained crew, a product used to its data sheet, and a thickness written down before we start.
Hidden roof sheathing. We spray only decks that are dry and sound.
Hard removal. Foam is stuck to the wood on purpose, which makes it slow to take out. That's why we size and place it right the first time. If you already have foam that needs to come out, see insulation removal.
Foam put in at the right thickness, with the barrier the code asks for, is not where the trouble comes from.
Stay out of the house while we spray, and wait out the maker's re-entry time before you go back in. The risk is during spraying and curing; once the foam has cured and is covered, that part is over.
On spray day, we ask everyone, pets included, to be out of the work area. We ventilate the space during the job. The re-entry time is set by the manufacturer for the product we use. We put that product and its time in your written scope so you're not guessing.
A strong chemical smell that lingers past the re-entry time means something went wrong. Call us and we'll come back and look.
No spray foam is harmless while it's being sprayed. Some products are sold as lower-odor, water-blown or partly plant-based. Compare them on the product data sheet and safety data sheet, not on the marketing. Those sheets list what's in the foam, how it should be applied and how long to stay out. We'll show you the sheet for the product we propose.
A sealed attic is allowed only when every condition in Ohio's code is met. We don't spray an attic roofline unless it is.
In climate zone 5, air-impermeable insulation such as closed-cell foam must be a Class II vapor retarder or have one in direct contact with its underside. Where only air-impermeable insulation is used, it goes directly on the underside of the roof sheathing. For condensation control in zone 5, the rigid board or air-impermeable layer must be at least R-20 (Ohio Section 806.5, Table 806.5).
Don't read that R-20 as the R-value to buy. It's the least foam that keeps the roof deck from sweating in winter. It isn't the insulation level for the house. Ohio's 2019 residential code asks R-49 for new attic work, and the R-value guide and attic insulation page explain that level.
So when you compare foam quotes, ask what R-value each one buys. A thin coat that clears R-20 and a roofline foamed to the attic level are different jobs at different prices. We write the product, the inches and the R-value into your scope, and we price the roofline to the R-value you choose. Thickness is what moves the price: see spray foam cost.
If a sealed attic doesn't fit your house, a vented attic with blown-in insulation may. We'll say which at the estimate.
Yes, spray foam has to be covered. Ohio's code (Section 316) says spray foam and other foam plastic must be separated from the living space by an approved thermal barrier, such as 1/2-inch drywall.
Attics and crawl spaces entered only for repairs or maintenance have their own rule. An ignition barrier may be used there instead. Examples are 1.5-inch mineral fiber, 1/4-inch wood structural panel, 3/8-inch gypsum board, or in attics 1.5-inch cellulose.
For you, that means exposed foam in a finished basement or a room gets drywall. We spray an intumescent coating over exposed foam in attics, crawl spaces and garages. The coating shows as its own line on your estimate. See spray foam cost for what moves that line.
Your written estimate for spray foam in Dayton and the Miami Valley spells out everything you're buying, so you can compare it with any other bid. It lists:
It's free, and if foam isn't the best answer for your house, we'll say so on it. Request your free estimate and we'll set a time to look.
Usually the old insulation comes out of the area first, because foam needs to stick to the wood or masonry. Wet or damaged material has to go either way. See insulation removal for how a cleanout works.
Yes. Plenty of jobs are a single rim joist, a crawl space or the room over a garage. We write each area on the estimate so you can do the rest later.
Yes, with injection foam. We drill small holes through the siding or mortar joints, fill the cavity and plug and patch the holes. The wall insulation page walks through it.
Call us or request your free estimate. We'll look at the house, tell you where foam fits and where it doesn't, and put the product, thickness and R-value in writing.
Licensed & insured · Free estimates