Dayton is in climate zone 5. Ohio's code sets a minimum R-value for each part of the house: R-49 in the attic, and separate numbers for walls, floors and basement walls. Here's what each number means, where to find the depth for R-49, and how to check your attic yourself. Or we'll measure it free and give you the R-value in writing.
R-value measures how well insulation slows heat. The higher the number, the slower heat leaves in winter and the slower summer heat gets in.
With any one material, more inches means more R. But materials give different R per inch, so two attics with the same depth can have very different R-values. That's why we talk in R-value, not inches.
Two things cut a rating down. Insulation that's squeezed loses R-value, and air moving through gaps carries heat around it. We seal those gaps first: why air sealing comes before insulation. To compare materials, see the main types of insulation.
Ohio's code sets R-49 as the minimum for new attic work. When an existing house is altered, the new work has to meet the code for new construction. So R-49 is the level we write into an attic estimate unless you ask for something else.
ENERGY STAR aims higher for zone 5. It recommends R-60 for an attic with no insulation. If you already have 3 to 4 inches, it recommends adding R-49 on top. That's guidance, not code. It's a good target for a house that's hard to keep warm.
Old insulation that's dry and clean can stay under the new layer. Here's when it should come out first. For how an attic job goes from start to finish, see attic insulation in Dayton.
There's no single depth for R-49. Every bag of blown insulation has a coverage chart that gives the settled depth for each R-value. That chart is the depth we blow to.
The material makes a real difference. Loose cellulose gives more R per inch than loose fiberglass, so R-49 of fiberglass sits deeper in the attic. Both work. They just reach R-49 at different depths.
For how settling and depth checks work, see blown-in fiberglass and cellulose.
Ohio's code asks for one of two things in a wood-frame wall:
That applies to a new wall and to a wall you open up in a remodel.
If a remodel takes your walls down to the studs, plan the insulation to that number before the drywall goes back up. For closed walls in an older house, see how we insulate existing walls.
A floor over a crawl space, garage or other unheated space needs R-30 in zone 5. The code also accepts insulation that fills the framing cavity, as long as it's R-19 or more. ENERGY STAR recommends the same R-30 under a floor.
Basement and crawl space walls follow a rule written 10/13. That means one of two things:
Floor or crawl space walls? Insulate the floor if the crawl space stays vented and dry, and the walls if it's damp or sealed. More on crawl space and floor insulation. For concrete walls and rim joists, see basement insulation.
None of these batts reaches R-20 by itself in a wall. A new 2x4 wall needs the continuous R-5 layer too. A new 2x6 wall needs a higher-rated batt or that same layer.
Never force a thick batt into a thin cavity. More on fiberglass batts and rolls.
Dayton is in climate zone 5A. Montgomery County is 5A on every version of the zone map, the older one and the 2021 one. So both the zone 5 code numbers and ENERGY STAR's zone 5 levels apply to your house.
Here, insulation mostly works against winter cold. Dayton has about 5,150 heating degree days a year against about 1,150 cooling degree days (1991-2020 average). Degree days measure how cold or hot a year runs. That's why Dayton's numbers come from the cold zone 5 row.
Ohio uses one statewide residential code, including its energy chapter. Whether it is enforced where you live depends on whether your area has a certified building department. Where the code is enforced, no local code may differ from it, and no town can adopt a different edition.
Dayton builds to the 2019 Residential Code of Ohio, in force since July 1, 2019. Its energy chapter sets the numbers above. Permit rules differ from town to town. See who issues permits around Dayton.
You can measure your own attic safely. You need a flashlight, a tape measure and a dust mask.
If you see gray-brown, pebbly vermiculite, stop and leave it alone. It should be tested before anyone disturbs it. Here's what to do about vermiculite.
Or let us measure it: book your free attic check.
No. R-30 is below what Ohio's code asks for new attic work, and below ENERGY STAR's zone 5 levels. If your attic is around R-30 now, we add insulation on top of what's there until it meets code.
A higher R-value always slows heat more. But each extra inch saves less heat than the inch before it. Past the right level for that part of the house, the gain gets small.
Usually the attic. It's open and easy to reach, and it's the easiest place to add a lot of R-value in one visit. Walls are worth doing too, but filling a closed wall takes more work.
We'll measure your attic in several places and tell you in writing your R-value now and what it takes to reach code. Call us or book your free check online.